21
IM-HC 599871 0321 RABS
Product Information
2.4 Technical Data
2.4.1 Specifications for Electronic Components
Control Unit
Underwriters Laboratory (UL) conformity
UL 60730-1
UL 60730-2-9
Federal Communication Commission (FCC)
FCC ID: 2AT95-RABS916CU
Innovation, Science and Economic Development (ISED) Canada IC: 25267-RABS916CU
Dimensions W × H × D
10.23 × 2.75 × 1.77 inches
Weight
16.9 oz
Maximum number of circuit hubs / powerheads
12
Maximum number of thermostats
8
Maximum number of range extenders
2 (operate in parallel, not in series)
Relative humidity minimum–maximum
5 to 95%
Ambient temperature minimum–maximum
32 to 122° F
IP Code
IP 20
Input voltage
120V AC, 50/60 Hz
Operating voltage
24V DC
Power consumption maximum (12 active circuits)
45 W continuous output
Backup battery: type (size)
Lithium button cell (CR2032)
Cable size range
26 to 14 AWG
Radio Connection
Communication direction
bi-directional
Frequency
916 MHz
Range in open space
> 230 ft.
Range in buildings
Approximately 80 feet
Supply Sensor
Underwriters Laboratory (UL) conformity
UL 60730-1
UL 60730-2-9
Thermistor dimensions d × L
0.16 × 0.35 inch
Sensor type
Contact sensor / NTC 10 kΩ
Measuring range minimum–maximum
32 to 149° F
Cable length
31.50 inches
Cable specifications
26 AWG, 2 wire
Plug
2-socket
Housing for supply sensor
Approximately 0.47 × 1.02 inch