3 Handling
3.1
Storage
For storage, comply with the requirements specified in the applicable
regulations, see
Ä
„Regulations from section: Storage“ on page 6
:
n
Store rods on even, clean surfaces.
Storage outside in closed, original packaging is possible for a period of
up to three months. In this instance, protect the packaging from
damage due to rain or high levels of humidity.
3.2
Assembly information
3.2.1
Mounting instructions
NOTICE!
Material damage due to thread locker containing solvents!
Thread lockers containing solvents can lead to material
damage and leaks in plastic parts of pipe connections. This
may lead to water damage.
– As a sealant, only use commercially available hemp
together with thread sealing paste or certified sealing
tape for potable water.
– Please contact the Viega Service Center if you have any
questions.
System components may, in some cases, become damaged through
transportation and storage.
n
Check all parts.
n
Replace damaged components.
n
Do not repair damaged components.
n
Contaminated components may not be installed.
Checking system components
Handling
Viega Smartpress