5- RECOMMENDATIONS TO THE INSTALLER
.
- Clean the working area.
- Explain the user the operation and maintenance of the equipment in detail.
- Explain to the user that, BEFORE SWITCHING ON THE UNIT
one window must have a 3 cm opening and all other vents must be closed.
This opening will allow hot air to be expelled from the interior.
- Wet the evaporator immediately after installation in order to fast start cooling.
- Provide the owner with the Viesa User's Manual and warranty information.
6- GENERAL MAINTENANCE
The equipment will delay in cooling until the evaporator is totally wet.
Do not use fuses higher than 15 Amp.
The equipment will deactivate automatically due to low tension so
as to prevent damages to the battery.
Use only clean water.
Foresee replenishment of water taking into account that the
equipment consumes between 2 and 5 litres per hour depending on
the ambient temperature.
When performing maintenance of the equipment or if
the evaporator unit's cover or the upholstery cover are removed,
the system MUST NOT BE SWITCHED ON and
you must not switch it on with any of these elements removed.
Keep the tank clean. Every 200 hours of use
- Drain all the water from the tank by removing the drain
plug.
.
- Rinse with clean water thoroughly.
- Pour one bottle of Viesa Scented Cleansing Fluid.
Each 6 months change the package of granulated Calfa Bas crystals.
VIESA SCENTED FLUID (EVERY 200 HOURS OF USE)
GRANULATED CALFA BAS EACH 6 MONTHS
Do not use chemical products to clean the control panel.
During short stops leave the equipment on so as to keep the cabin
- Fill-up the tank with clean water.
fresh.
System must be turned off when exhaust fumes, pesticides or toxic
particles could enter the cab through the system.