83
Coding in the delivered condition
Possible change
25:50
Stop temperature for
thermostat function
50 °C.
Start temperature for
thermostat function
≤
stop temperature for ther-
mostat function:
Thermostat function e.g.
for reheating. Switching
output
sS
is switched off
when the temperature at
sensor
/
exceeds the
start temperature for the
thermostat function.
Start temperature for
thermostat function >
stop temperature for ther-
mostat function:
Thermostat function e.g.
for utilising excess heat.
Switching output
sS
is
switched off when the
temperature at sen-
sor
/
falls below the
start temperature for the
thermostat function.
25:0
to
25:100
Start temperature for ther-
mostat function is adjusta-
ble from 0 to 100 K
26:1
Priority for DHW cylinder
1 – with alternate heat-
ing
Only when setting code
20:8.
26:0
Priority for DHW cylinder 1
– without alternate heating
26:2
Priority for DHW cylinder 2
– without alternate heating
26:3
Priority for DHW cylinder 2
– with alternate heating
26:4
Alternate heating without
priority for one DHW cylin-
der
Code 2
Solar
(cont.)
5692 860 GB