The following relay outputs can be controlled subject to system design:
Display
Explanation
Base load start
Burner operates at minimum output; heating circuit pump
A1 is on
Full load start
Burner operates at maximum output; heating circuit pump
A1 is on
Output Internal start
Internal output
sA
(cylinder primary pump) enabled
Htg circ pump HC2 start
Heating circuit pump output enabled (extension to heat-
ing circuit with mixer)
Mixer HC2 open
"Mixer open" output enabled (extension to heating circuit
with mixer)
Mixer HC2 close
"Mixer closed" output enabled (extension to heating cir-
cuit with mixer)
Htg circ pump HC3 start
Heating circuit pump output enabled (extension to heat-
ing circuit with mixer)
Mixer HC3 open
"Mixer open" output enabled (extension to heating circuit
with mixer)
Mixer HC3 close
"Mixer closed" output enabled (extension to heating cir-
cuit with mixer)
Outp. int. exten. H1 start
Output at internal extension H1/H2 enabled
EA1 output 1 start
Contact P - S on plug
aBJ
for extension EA1 closed
Solar circuit pump start
Solar circuit pump
sF
output at solar control module SM1
enabled
Solar circ pmp min start
Solar circuit pump output at solar control module SM1
switched to minimum speed
Solar circ pmp max start
Solar circuit pump output at solar control module SM1
switched to maximum speed
Sol. output
sS
start
Output
sS
at solar control module SM1 enabled
SA 104 output 1 start
DHW circulation pump output
sK
SA 104 output 2 start
Output heating circuit pump A1
sÖ
SA 104 output 3 start
Diagnosis and service scans
Checking outputs (actuator test)
(cont.)
5692 860 GB