6
Connections
A
B
C
D
E
F
G
H
Fig. 1
A
Female connection for immersion heater
B
DHW with high limit safety cut-out
C
Cylinder temperature sensor
D
Heating water flow
E
DHW circ.
F
Heating water return
G
Connection for thermometer sensor
H
Cold water/drain outlet
Siting information
!
Please note
The thermal insulation must not be able to come
into contact with naked flames.
Exercise caution when welding and soldering.
!
Please note
To prevent material losses, install the DHW cyl-
inder in a room free from draughts and risk of
frost.
When not in use, the DHW cylinder must be
drained if there is a risk of frost.
■
Provide adequate clearance from the wall so that the
Vitosolic 100 can be operated (if installed).
■
Use the adjustable feet to level the DHW cylinder.
Note
Never
extend the adjustable feet beyond a total
length of 35 mm.
Product information
5838690