55
7.
4x
9.
8.
Fig. 41
10.
Clean the heating surfaces of the flue gas heat
exchanger.
11.
Reinstall the flue gas heat exchanger in reverse
order. At the same time, ensure that the flue gas
temperature sensor is pointing forwards.
Torque for nuts: 5 Nm
Checking the condensate drain and cleaning the trap
Danger
Contact with condensate can be harmful to
health.
Never let condensate touch your skin or eyes
and do not swallow it.
Wear personal protective equipment.
Commissioning, inspection, maintenance
Cleaning the heat exchanger heating surfaces
(cont.)