22
■
The condensate hose and safety valve discharge
pipe are separate pipes. The pipes meet the temper-
ature requirements for CE certification.
■
We recommend connecting the condensate hose
and the safety valve discharge pipe internally via a
common drain pipe to the domestic waste water sys-
tem, either directly or via a tundish.
■
If the common drain pipe is routed outside the build-
ing, use a pipe with at least
7
30 mm and protect
this pipe from frost. Avoid long external pipe runs.
!
Please note
If the condensate hose, safety valve discharge
pipe or common drain pipe freezes, this can
result in faults and damage to the appliance.
Always protect all drain/condensate pipes
against frost.
■
Observe local building regulations.
Observe local waste water regulations.
Note
Fill the trap with water before commissioning.
Aligning the appliance
1.
2.
SW17
3.
A
Fig. 11
3.
Bring the Vitotronic control unit into the mainte-
nance position (see Fig. 53, page 102) and align
the side panels using screws
A
.
Installation sequence
Condensate connection
(cont.)
5678 044 GB
Installation