160
Rated voltage
230 V
Rated frequency
50 Hz
Rated current
6 A
Protection class
I
IP rating
IP X 4 D to
EN 60529
Permissible ambient temperature
■ during operation
0 to +40 °C
■ during storage and
transport
-20 to +65 °C
Electronic tempera-
ture limiter setting
82 °C
Temperature limiter
setting
100 °C (fixed)
Line fuse (power sup-
ply)
max. 16 A
Rated output range
at T
V
/T
R
50/30 °C
kW
4.8 to 19
6.5 to 26
at T
V
/T
R
80/60 °C
kW
4.3 to 17.5
5.9 to 24.1
Rated output for DHW heating
kW
4.3 to 17.5
5.9 to 26.4
Rated heat input range
kW
4.5 to 17.9
6.2 to 29.7
Power consumption
W
90
105
Connection values
in relation to the max. load
Natural gas H
m
3
/h
1.89
3.23
LPG
kg/h
1.40
2.39
Product ID
_
-0085BU0051
Cylinder heat-up time, 15 to 60 °C
19 mins
Cylinder heat-up time, 70% volume
15 mins
Note
The supply values are only for documentation purposes (e.g. in the gas contract
application) or to estimate the supplementary volumetric settings. Because of factory
settings, the gas pressure must not be altered from these values. Reference: 15 °C,
1013 mbar.
Specification
Specification
5412 755 GB