Wall-mounted Manifold 65-2
[Art.-No. LVW-65-2 / 7387823]
Wall-mounted Manifold 65-3
[Art.-No. LVW-65-3 / 7388040]
Wall-mounted heat distributor; forward- and return-flow distributor packed with intermediate insulation (chamber size 55
mm x 55 mm); distributor insulated all around and covered with powder coated steel plates.
Special design for Siemens motor-operated valves, models VXG 25/ SSY 319 (Art. No: ZV-3-25 / 7387484). Especially
suited for the Pyromat burner series with accumulator operation (burner output up to 65 kW).
Connections: Burner:
Forward flow/return flow: 1½" IG on the left or right side
Accumulator: Forward flow/return flow: 1½" IG on the left or right side
Consumer:
Forward flow/return flow: 1" AG at top with bypass, for two or three groups (last digit of the
Art. No.)
Incl. bolted connection for motor-operated valves, Siemens models VXG 25/ SSY 319 (Art.
No: ZV-3-25 / 7387484).
Heat Distributor Connection LVW-65
[Art. No. LVW-65-V / 7387862]
Connecting two model LVW-65- manifolds produces a manifold for four to six consumer groups. The connection is
assembled at the factory to assure an accurate fit.
Heat Distributor for Burner Design 65-2
[Art. No. LVK-65-2 / 7387815]
Heat Distributor for Burner Design 65-2
[Art. No. LVK-65-2 / 7387947]
Heat distributor for burner design; forward- and return-flow distributor packed with intermediate insulation (chamber size:
55 mm x 55 mm);
distributor insulated all around and covered with powder-coated steel plates.
Special design for Siemens motor-operated valves, models VXG 25/ SSY 319 (Art. No: ZV-3-25 / 7387484). Especially
suited for the PYROMAT burner series with accumulator operation (burner output up to 65 kW).
Connections: Boiler:
Forward flow/return flow 1 1/2 " IG on the left side
Accumulator: Forward flow/return flow 1 1/2 " IG on the left side
Consumer:
Forward flow/return flow: 1" AG at top with bypass, for two or three groups (last digit of the
Art. No.)
Incl. bolted connection for motor-operated valves, Siemens models VXG 25/ SSY 319 (Art.
No: ZV-3-25 / 7387484).
Note: This burner design is not possible with PYROMAT-DYN - standard version, hydraulically switched heat storage
tank
LVW-65-3
LVW-65-2
LVW-65-V
suspension
A:
PYROMAT
ditto dimensions
LVW-65-2
LVW-65-3
se
e