UP arrow
-scrollsthroughmenuitems,increasesvalues,activatesmanualdefrosting
function.
•
DOWN arrow
-scrollsthroughmenuitems,decreasesvalues,programmablebyparameter.
•
FNC key
-exitfunction,programmablebyparameter.
•
SET key
-accessessetpointsandmenus,confirmscommands,displaysalarms.
At start-up the instrument performs a lamp test - for a few seconds the display and the LEDs
blink to verify their integrity and correct operation.
The cabinet controller is pre-programmed at the factory. Do not adjust the set values.
Adjusting the thermostat or defrosting values may cause the evaporator to freeze. In
case of problems, please contact your nearest servicing organisation or dealer.
NOTE
The instrument has two main menus: the Machine Status menu and the Programming menu.
3.2.1.2. Machine Status menu
1. PressSETquicklytoaccesstheMachineStatusmenu.Ifalarmsarenotpresent,thelabel
"SEt"appears.
2. ScrollthroughtheotherfoldersinthemenuwithUPorDOWN.
Folders: Pb1 (probe 1 value folder), Pb2 (probe 2 value folder), SEt (setpoint setting folder).
Adjusting the temperature
a. Press SET quickly to access the Machine Status menu. The label of the "SEt" folder
appears.
b. Press SET again to display the Setpoint value. The value appears on the display.
c. Change the Setpoint value with UP or DOWN within 15 seconds.
Displaying probes
When the appropriate label appears, press SET to display the probe value associated to it.
3.2.1.3. Programming menu
1. PressSETformorethan5secondstoentertheProgrammingmenu.
2. ScrollthroughthefolderswithUPorDOWN.
3. PressSETtoenterthedesiredfolder. Thelabelofthefirstvisibleparameterappears.
4. ScrollthroughtheotherparameterswithUPorDOWN.
5. PressSETquicklytoselectthedesiredparameter.
6. SetthedesiredvaluewithUPorDOWN.
7. PressSETtoconfirmtheselectionandmovetothenextparameter.
If you do not press any of the keys for 15 seconds or press FNC to exit the function,
the last value on the display is verified and you return to the previous display.
NOTE
Factory settings
The parameter settings are pre-adjusted at the factory. The settings should not be changed
unless necessary.
3.2.1.4. Manual activation of defrosting cycle
Press UP for 5 seconds to manually activate the defrosting cycle.
10
Version05/2015
ENGLISH