3. Electrical connections
The symbol marked on the cabinet (a lightning bolt inside a triangle) indicates that
there are components and wires under the cover containing live voltage. Only
personnel qualified to install and service electrical equipment are permitted access
to areas that contain live voltage.
NOTE
Check the voltage and size of the fuse required on the rating plate attached to the cabinet. The
supply socket must be earthed and protected by a 10 A slow fuse. No other appliances may be
connected to the same fuse.
All electrical connections must be carried out by approved and qualified personnel
and comply with all IEE and local regulations, failure to do this could result in
personal or fatal injury.
NOTE
4. Operation
The cooling is achieved by a fan evaporator system. The evaporator is located at the top of the
cabinet. The cold air is blown to the shelves via the air passage located in the back wall.
The cabinet is equipped with a Dixell XR40CX or NRC-100 controller.
In case the pressure rises to high, for example because of dirt in the condenser, the Dixell XR40CX
controller stops the machine from running and shows an error message (HA2).
NRC-100 controller turns off the cabinet's lights in case the pressure rises. See
figure
1 on the inside cover
for the location of the cabinet's light switch.
For more information on the different control systems, please see the corresponding
chapters.
4.1. Starting up
1. Connecttheplugtothesupplysocket.
The compressor and fans start operating.
2. Waitfor90minutesoruntilthedesiredtemperatureisreached.
The cabinet is now ready to be filled.
4.2. Loading cabinet
• Positiontheproductscarefully.
• Donotexceedtheloadlimit. Themaximumloadontheshelvesis100kgpermetre.
•
Do not place products so that they protrude over the front edge of the shelf or obstruct the
inlet grid.