Defrosting signals
Defrosting under way.
Probe failure alarm signals
Safety switch probe failure.
Contact service.
Evaporator probe failure.
Contact service.
Thermostat probe failure. Contact
service.
Cabinet temperature probe failure.
Contact service.
Cabinet failure alarm signals (condenser overheat)
Cabinet switched off due to
overheating. Check the condenser
first and clean it by opening the hatch
from the base and vacuuming the
condenser, if needed. If the fault
persists, contact service.
4.5.2. Checking temperature settings
1. PresstheSETkeybriefly.
Setpoint value appears in the display.
The normal temperature view also reappears if you do not touch any button for five (5)
seconds.
4.6. Automatic defrosting
The cabinet is equipped with an automatic defrosting device. The NRC-100 unit controls the
operation periods and the defrosting process. Defrosting is performed three (3) times a day
(electric defrosting). Drain water from defrosting is automatically led to a hot gas evaporation tray
or to an electrically heated evaporation sump depending on the cabinet model. The temperature
inside the cabinet rises by a few degrees during defrosting.