In the FC model the F/C (-/+) switch is located inside the machinery compartment. See
figure 1
on the inside cover
.
4.4. NRC-100 control device
The type of the control device depends on the cabinet.
NOTE
NRC-100 is a cabinet controller that automates cabinet defrosting by means of a thermostat and
temperature sensor.
4.4.1. Display messages
In normal status, the display shows cabinet temperature.
Defrosting signals
Waiting for other cabinets
when synchronising defrost.
Pull down. Cooling until
expected temperature is
reached.
Defrosting under way.
Probe failure alarm signals
Cabinet temperature probe
failure. Contact service.
Evaporator probe failure.
Contact service.
Thermostat probe failure. Contact
service.
Safety switch probe failure.
Contact service.
Safety switch probe failure. Contact
service.
Cabinet failure alarm signals (condenser overheat)
Cabinet switched off due to
overheating. Check the
condenser first and clean it
by opening the hatch from
the base and vacuuming the
condenser, if needed. If the
fault persists, contact
service.
Safety switch is on and cabinet lights
off (alarm signal). Check the
condenser first and clean it by
opening the hatch from the base and
vacuuming the condenser, if needed.
Push the FNC button or switch the
cabinet off and then back on.
8888
or other unusual signal on the display may indicate start failure. Disconnect
the cabinet from the mains supply and reconnect it. If the unit does not start
normally, contact the service.
NOTE
7
Version03/2015
ENGLISH