VITOGAS 050

Cast iron hot water heating boiler

550 to 1050 MBH / 161 to 308 kW

5167 455 v1.2 01/2004

Technical Data Manual

Model Nos. and pricing: see Price List

Vitogas 050

RS Series

Gas-/Propane-Fired Boiler

cast iron construction
atmospheric
single- or two-stage burners
Heating input: 550 to 1050 MBH

161 to 308 kW

Summary of Contents for RS-11

Page 1: ...050 MBH 161 to 308 kW 5167 455 v1 2 01 2004 Technical Data Manual Model Nos and pricing see Price List Vitogas 050 RS Series Gas Propane Fired Boiler cast iron construction atmospheric single or two stage burners Heating input 550 to 1050 MBH 161 to 308 kW ...

Page 2: ...eat transfer to avoid stress fractures H Large diameter stainless steel burners provide quiet reliable performance combustion efficiency of 85 H Optimal operation due to wide water passageways and a wet base sectional design H Although the heat exchanger block is fully factory assembled it may be shipped in section blocks for field assembly to accommodate tighter handling H Problem free transport ...

Page 3: ...36 921 53 1366 47 1195 36 921 60 1531 73 1867 34 883 49 1255 53 1366 47 1195 49 1255 60 1531 73 1867 34 883 62 1582 53 1366 47 1195 62 1588 60 1531 73 1867 Weight boiler with insulation lbs burners and packaging kg 1280 582 1709 777 2138 972 Boiler water content USG ltr 20 77 28 106 35 134 Max operating pressure psig kPa 60 414 60 414 60 414 Boiler connections Boiler supply and return Boiler drain...

Page 4: ...er Water Supply FGC Flue Gas Collar GC1 Main Gas Connection GC2 Pilot Gas Connection PC Pilot Cover Plate PRV Pressure Relief Valve Connection FGC BWS GC1 BWR Total width Total depth Height 2 Height 1 Height Depth GC2 PRV PC BD 4 110 mm 19 481 mm 32 830 mm 50 1284 mm 15 400 mm 52 1335 mm ...

Page 5: ...ith draft hood 1 set of boiler ID hardware coding card and technical literature 1 carton of installation fittings 50 psig pressure relief valve air vent pressure gage drain valve and installation fittings 1 cleaning brush 1 carton with boiler control unit Boiler Control Alternatives Vitotronic 100 KK10 enhanced boiler control for high temperature heating systems Vitotronic 100 KW10 enhanced boiler...

Page 6: ... the boiler vent pipe collar and at the chimney connection Ensure any test port for combustion values is sealed as well The chimney connection length between the boiler vent pipe collar and the chimney must be installed with insulation We recommend consulting a reputable chimney installer for advice in project specific circumstances Oxygen diffusion barrier underfloor tubing The boiler warranty do...

Page 7: ...d verified Proper installation and functionality in the field is the responsibility of the heating contractor Without a mixing valve with Vitotronic 100 Model KK10 or KW10 control Heating circuit Spring loaded flow check valve Circulation pump Pressure relief valve Precharged expansion tank Gas connection The installation of the check valve to restrict gravity circulation in the heating supply pip...

Page 8: ...on pump Pressure relief valve Precharged expansion tank Domestic hot water storage tank indirect fired DHW Pump Module Gas connection The installation of the check valve to restrict gravity circulation in the heating supply pipe prevents uncontrolled heat flow to the heating system by gravity during priority switching of domestic hot water heating or during summer operation 5167 455 v1 2 ...

Page 9: ... Circulation pump Pressure relief valve Precharged expansion tank Domestic hot water storage tank indirect fired 4 Way mixing valve Gas connection The installation of the check valve to restrict gravity circulation in the heating supply pipe prevents uncontrolled heat flow to the heating system by gravity during priority switching of domestic hot water heating or during summer operation 5167 455 v...

Page 10: ...essory Kits Heating circuit Spring loaded flow check valve Circulation pump Pressure relief valve Expansion tank Domestic hot water storage tank indirect fired 3 Way mixing valve Gas connection The installation of the check valve to restrict gravity circulation in the heating supply pipe prevents uncontrolled heat flow to the heating system by gravity during priority switching of domestic hot wate...

Page 11: ...11 5167 455 v1 2 ...

Page 12: ...ssmann ca mail viessmann ca Viessmann Manufacturing Company U S Inc 45 Access Road Warwick Rhode Island 02886 USA Tel 401 732 0667 Fax 401 732 0590 www viessmann us com mail viessmann us com 12 5167 455 v1 2 Technical information subject to change without notice Printed on environmentally friendly recycled and recyclable paper ...

Reviews: