Adjustment channels
Channel
Sub channel 1
Sub channel 2 Factory setting
Change to
Description
Page
OCMI2
OFF
Collector minimum limitation option 2
46
CMIN2
10.0 °C [50.0 °F]
Minimum collector temperature 2
46
OTCO2
OFF
Evacuated tube collector function option 2
46
TCST2
07:00
Evacuated tube collector starting time 2
46
TCEN2
19:00
Evacuated tube collector ending time 2
46
TCRU2
30 s
Evacuated tube collector runtime 2
46
TCIN2
30 min
Evacuated tube collector standstill interval 2
46
LLOGI >
Loading logic
LOGIC
PRIO
Priority logic
48
PRIO1
1
Priority logic tank 1
48
PRIO2
2
Priority logic tank 2
48
OSTS
OFF
Tank set option
50
TST1
45 °C [120 °F]
Set tank temperature tank 1
50
TST2
45 °C [120 °F]
Set tank temperature tank 2
50
TSTS3
45 °C [120 °F]
Set tank temperature tank 3
50
tLB
2 min
Loading break time
48
tRUN
15 min
Circulation runtime
48
PSPEE
OFF
Pause speed option
51
PDELA
OFF
Pump delay option
51
COOL >
Cooling functions
OSYC*
OFF
System cooling
51
OSTC
OFF
Tank cooling
52
PUMP >
Speed
PUMP1
OnOF
Speed variant pump 1
45
PUMP2
OnOF
Speed variant pump 2
45
PUMP3
OnOF
Speed variant pump 3
45
MAN >
Manual mode
MAN1
Auto
Manual mode 1
56
MAN2
Auto
Manual mode 2
56
MAN3
Auto
Manual mode 3
56
MAN4
Auto
Manual mode 4
56
BLPR >
OFF
Blocking protection
56
OHQM >
OFF
Energy metering option
58
DATE>
Enter date
60
LANG >
dE
Language
61
UNIT >
°C
Unit
60
OSDC >
SD card option
61
CODE
0000
User code
RESET
OFF
Factory setting
* are blocked against each other