en-US/C
A
63
Channels
Channel
Sub channel 1
Sub channel 2 Factory setting
Change to
Description
Page
n1LO
30 %
Minimum speed
45
n1HI
100 %
Maximum speed
45
PUMP2
OnOF
Speed variant pump 2
45
n2LO
30 %
Minimum speed
45
n2HI
100 %
Maximum speed
45
PUMP3
OnOF
Speed variant pump 3
45
n3LO
30 %
Minimum speed
45
n3HI
100%
Maximum speed
45
OTDIS >
Thermal disinfection option
57
PDIS
01:00
Monitoring period (interval)
57
DDIS
01:00
Disinfection period
57
TDIS
60 °C [140 °F]
Disinfection temperature
57
SDIS
00:00
Starting time
57
TSDIS
3
Temperature sensor for disinfection
58
OTDIS
ON
Deactivation Thermal disinfection
58
OPARR >
Parallel relay option
58
PARRE
2
Parallel relay
58
INVER
OFF
Inversion
58
OHQM >
Energy metering option
58
FTYPE
1
Flow rate detection type
58
FMAX
6 l/min
Adjustable maximum flow rate
59
FIMP
1 l/lmp
Pulse rate
59
MEDT
1
Antifreeze type
59
MED%
40
Antifreeze concentration
59
SFHQM
1
Sensor flow HQM
59
SRHQM
4
Sensor return HQM
59
DATE>
Enter date
60
TIME
12:00
Time
60
YYYY
2010
Year
60
MM
03
Month
60
DD
15
Day
60
LANG >
dE
Language
61
MAN >
Auto
Manual mode
56
BLPR >
OFF
Blocking protection
43
UNIT >
°C
Unit
60
OSDC >
SD card option
61
CODE
0000
User code
RESET
OFF
Factory setting
* are blocked against each other
Summary of Contents for SCU345
Page 71: ...en US CA 71 Notes ...