18
4.
Should the condensate drain run partially through
unheated rooms, provide thermal insulation or a
ribbon heater around the condensate drain on site.
!
Please note
Freezing condensate in the heat pump leads
to appliance damage.
If required, fit the condensate drain with ther-
mal insulation or a ribbon heater on site.
Condensate drain via trap
Ø 20
≥
60
Fig. 14
Condensate drain via water seal
Ø 20
≥
60
Fig. 15
Connections on the DHW side
The DHW heat pump is designed to be connected per-
manently to the water supply.
For connecting the DHW side, observe DIN 1988,
DIN 4753 and EN 806.
Furthermore observe the following:
■
Connect all pipework with detachable fittings.
■
Equip the DHW circulation pipe with a DHW circula-
tion pump, check valve and time switch. Gravity
operation is possible only to a limited extent.
Installation sequence
Connecting the condensate drain
(cont.)