20
Maximum collector area and sizing information
DHW heat pump technical guide
Connecting the solar collectors
Solar collector installation instructions
For connections to the DHW heat pump, see pages 9
and 22.
Note
■
The cylinder temperature sensor is fitted at the fac-
tory.
■
A high limit safety cut-out (accessories) for stopping
the solar circuit pump
must
be fitted.
High limit safety cut-out (accessories) installa-
tion instructions
Note
In outdoor air mode, the immersion heater (accesso-
ries) is essential.
Type T0S-ze: External heat generator
For connections to the DHW heat pump, see pages 9
and 22.
Fitting the temperature sensor
!
Please note
Damage to the connecting cables and sensor
leads (capillaries) causes malfunctions.
■
The connecting cables and sensor leads must
not come into contact with hot components.
When routing and securing connecting cables
and sensor leads, ensure that the maximum
permissible temperatures for these cables/
leads are not exceeded.
■
Do not kink the capillary tubes.
Installation sequence
Type T0S-ze: Solar thermal system
6136003
Installation