Temperature sensor for heating circuit
Part no. 7528 121
■ Contact temperature sensor Pt1000
■ As a flow temperature sensor
Buffer temperature sensor
Part no. ZK01 320
– 3 pce, for operation with heating water buffer
cylinder
Part no. ZK01 535
– 5 pce, for operation with heating water buffer
cylinder
Immersion temperature sensors with connecting lead, for capturing
temperatures in the heating water buffer cylinder
Specification
Lead length
5 m, fully wired
IP rating
IP 60 to EN 60529, ensure
through design/installation
Sensor type
Viessmann Pt1000
Permissible ambient temperature
– During operation
0 to +90 °C
– During storage and transport
-20 to +70 °C
On-site extension of the connecting lead:
■ 2-core lead, length up to 60 m with a cross-section of 1.5 mm
2
(cop-
per)
■ Never route this cable immediately next to 230/400 V cables.
Set of temperature sensors for the solar circuit
Part no. ZK01 271
Components:
■ Collector temperature sensor
■ Cylinder temperature sensor
Collector temperature sensor
Immersion temperature sensor as collector temperature sensor with
connecting lead for installation in the solar collector
Lead length
5 m, fully wired
IP rating
IP 32 to EN 60529, ensure
through design/installation
Sensor type
Viessmann Pt1000
Permissible ambient temperature
– During operation
-20 to +180 °C
– During storage and transport
-20 to +70 °C
On-site extension of the connecting lead:
■ 2-core lead, length up to 60 m with a cross-section of 1.5 mm
2
(cop-
per)
■ Never route this cable immediately next to 230/400 V cables.
Cylinder temperature sensor
Immersion temperature sensor as cylinder temperature sensor with
connecting lead
In systems with DHW cylinders from Viessmann, the cylinder temper-
ature sensor is installed directly into the sensor well of the threaded
elbow in the heating water return.
Lead length
5 m, fully wired
IP rating
IP 32 to EN 60529, ensure
through design/installation
Sensor type
Viessmann Pt1000
Permissible ambient temperature
– During operation
0 to +90 °C
– During storage and transport
-20 to +70 °C
On-site extension of the connecting lead:
■ 2-core lead, length up to 60 m with a cross-section of 1.5 mm
2
(cop-
per)
■ Never route this cable immediately next to 230/400 V cables.
Mixer extension kits
3 heating circuits with mixer, 2 heating circuits with mixer plus DHW
heating or one heating circuit with mixer, one solar circuit plus DHW
heating can be directly connected to the Ecotronic of automatically
charged boilers.
Direct connection of solar circuit or DHW heating
No extension kit is required for connecting the solar circuit or the DHW
heating directly to the Ecotronic.
Direct connection of heating circuit with mixer
When directly connecting the heating circuit with mixer, only an exten-
sion kit with mixer motor and flow temperature sensor is required. No
additional mixer PCB has to be incorporated into the control system.
Additional heating circuit with mixer
If an additional heating circuit with mixer cannot be directly connected
to the Ecotronic, connect the additional heating circuit with mixer to the
Ecotronic via a KM BUS. This requires an extension kit mixer motor
with mixer PCB for incorporation into the control system.
Ecotronic control unit for Vitoligno 300-H
(cont.)
26
VIESMANN
VITOLIGNO 300-H
3
5672 507 GB