Pellet supply from the pellet silo to the boiler
Vitoligno 300-H: Pellet supply by vacuum system (vacuum sys-
tem + silo)
Can be used if the pellet silo is not immediately adjacent to the instal-
lation room. Pellets can be transported up to a distance of 15 m and
to a height differential of 5 m.
A
B C D E F
H
K
G
A
Pellet silo
B
Return air connector
C
Fill connector
D
Pressure hose
E
Suction hose
F
External suction turbine
G
Vitoligno 300-H
H
Suction hose
K
Pressure hose
Fuel discharge