Setting of the maximum temperature inside the DHW cylinder.
Renewed heating will be prevented after this temperature has been reached,
until the temperature has dropped by at least 5 K.
Danger
DHW at temperatures > 60 °C will lead to scalding.
At these temperatures, install anti-scalding protection on site.
Access
&
"
Device settings
"
&
"
Programming
"
&
"
DHW
"
&
"DHW cylinder maximum"
(
T
/
U
)
Standard setting
60 °C
Setting range
20 to 80 °C
Hysteresis; DHW instantaneous heating water heater/hysteresis
These settings determine the deviation from the set DHW cylinder temperature
("
DHW cylinder temp.
") at which the cylinder heating is switched on and off by
the heat pump ("
Hysteresis
").
If an instantaneous heating water heater is also installed, the "
DHW E heating
hysteresis
" is also relevant.
DHW cylinder maximum
149
DHW control settings