Note
This setting influences the natural cooling function. If the setting is
too low
, the
dew point monitor switches the cooling function off prematurely, subject to the
cooling curve (see page 155).
Access
&
"
Device settings
"
&
"
Programming
"
&
"
Heating circuit
"
&
"
Heating circuit 1/2
"
&
"Min. flow temp."
(
1
/
!
)
Standard setting
10 °C
Setting range
1 to 30 °C
DHW during party mode
This setting defines whether the DHW cylinder (setting "
Yes
") is heated first or
whether the system switches directly to heating mode (setting "
No
") when party
mode has been activated (see operating instructions).
Access
&
"
Device settings
"
&
"
Programming
"
&
"
Heating circuit
"
&
"
Heating circuit 1/2
"
&
"DHW during party"
("
YES
"/"
NO
")
Standard setting
YES
Setting range
YES/NO
Excess reaction
Coordination of the heat drawn off in the secondary circuit when the heat pump
produces an excess of heat or the heat drawn by the secondary circuit is sud-
denly choked off.
Settings:
0
No heat drawn off
1
Heat will be drawn off only in case of a critical excess, i.e. if critical tem-
peratures were reached in the heat pump circuit or the minimum heat
pump runtime has not yet been reached
2
Heat will be drawn off, even if the excess heat being created is not critical
for the heat pump
Minimum flow temperature
(cont.)
156
Heating circuit control settings
55
92
968
GB
Summary of Contents for VITOCAL 200-G
Page 8: ...Certificates Declaration of conformity 201 Keyword index 202 Index cont 8 Index 5592 968 GB ...
Page 122: ...Main menu Information Menu structure overview information 122 Control settings 5592 968 GB ...
Page 187: ...Parts lists cont 187 Parts lists 5592 968 GB Service ...
Page 188: ...Parts lists cont 188 Parts lists 5592 968 GB ...
Page 189: ...Parts lists cont 189 Parts lists 5592 968 GB Service ...
Page 206: ...206 5592 968 GB ...
Page 207: ...207 5592 968 GB ...