Preconditions: Room temperature sensor installed and enabled.
This setting determines when the room temperature hook-up should be enabled
in addition to the weather-compensated control.
Settings:
0
No room temperature hook-up
1
Room temperature hook-up only in reduced mode
2
Room temperature hook-up only in standard mode
3
Room temperature hook-up in standard and in reduced mode
Access
&
"
Device settings
"
&
"
Programming
"
&
"
Heating circuit
"
&
"
Heating circuit 1/2
"
&
"Room temp. hook-up"
(
l
/
m
)
Standard setting
0
Setting range
0 to 3
Start optimisation
Operating instructions
Maximum flow temperature correction
Preconditions: Room temperature sensor installed and enabled.
Setting the maximum value, by which the flow temperature can be modified by
the room temperature hook-up.
Room temperature hook-up
158
Heating circuit control settings