Setting parameters
Setting range
Standard
setting
Commission-
ing
Power-OFF
No/Yes
Yes
Electric heating
No/Yes
Yes
DHW with electric
No/Yes
Yes
Max. flow temperature
5 to 75 °C
65 °C
Heater rod delay
0:00 to 5:00 h
0:30 h
Electric heating
threshold
10 to 30000 K
∙
min
300 K
∙
min
E-heating max. stage
1 to 3
3
Internal hydraulics
Heat pump for drying
buildings
No/Yes
No
Time for drying build-
ings
0 to 30 days
0 days
("Off")
Flow hysteresis
0.5 to 5.0 K
2.0 K
Internal pump run-on
00:10 to 05:00 min
02:00 min-
utes
Max. steps, three-way
valve
-30000 to 30000
320
DHW
DHW cylinder tem-
perature
10 to 70 °C
50 °C
DHW program tem-
perature
Seven-day program
OFF
DHW circulation pump
program
Seven-day program
OFF
Operating mode
0 to 6
*
1
4
DHW cylinder max.
20 to 80 °C
60 °C
Hysteresis, DHW elec-
tric heating
2 to 30 K
10 K
Hysteresis
1 to 10 K
7 K
Start optimisation
No/Yes
Yes
Stop optimisation
No/Yes
Yes
Auxiliary DHW func-
tion
No/Yes
No
Set DHW temperature
10 to 70 °C
60 °C
Cylinder volume for
HP
No/Yes
Yes
Control parameter report
(cont.)
192
Commissioning/service reports
55
92
968
GB
*1
0: Standby; 1: Reduced; 2: Standard; 3: Fixed value; 4: Rotary selector; 5: External;
6: Switching times.
Summary of Contents for VITOCAL 200-G
Page 8: ...Certificates Declaration of conformity 201 Keyword index 202 Index cont 8 Index 5592 968 GB ...
Page 122: ...Main menu Information Menu structure overview information 122 Control settings 5592 968 GB ...
Page 187: ...Parts lists cont 187 Parts lists 5592 968 GB Service ...
Page 188: ...Parts lists cont 188 Parts lists 5592 968 GB ...
Page 189: ...Parts lists cont 189 Parts lists 5592 968 GB Service ...
Page 206: ...206 5592 968 GB ...
Page 207: ...207 5592 968 GB ...