2.
Insert the corrugated pipes of the
connection set for the brine circuit
(supplied with the heat pump) into
the pipe sleeves of the heat pump.
Note
Do
not shorten
the corrugated
pipes. It will
not be possible to
seal
the connector at the shortened
end of the corrugated pipe.
Then
secure
the corrugated pipes
using the clamps provided and con-
nect to the on-site brine circuit
installation (see page 15).
Installation information -
brine circuit connection set.
3.
Fit the front top panel.
4.
Affix type plate to main PCB cover
(for position see illustration on
page 62).
Connections on the primary side of the heat . . .
(cont.)
74
Installation sequence
55
92
968
GB