Compressor power supply
A
Terminals at the control module
Recommended core cross-section:
1.5 mm
2
Note
The upstream fuses must have Z
characteristics.
Instantaneous heating water heater power supply
A
Terminals in the control panel
Max. fuse rating 16 A
Recommended core cross-section:
2.5 mm
2
The three heating elements are
switched by inserting jumpers across
X60.8, X60.9 and X60.10 in star for-
mation and must be connected to N.
230 V~ power supply, various tariffs
&
Three separate power cables
&
Selective power-OFF for compressor and instantaneous heating water heater
possible
The cross-section of the power supply lines must be appropriate for the con-
nected load of the relevant unit.
Power supply
(cont.)
93
Installation sequence
55
92
968
GB
Installation