29
Immersion heater 6 kW
Rated output in standard operation
kW
2
4
6
Rated voltage
3/N/PE 400 V
∼
/50 Hz
Rated current
A
8.7
Type SVKA/SVSA, 750 litres
Heat-up time from 10 to 60 °C
h
10
5
3.4
Capacity that can be heated with the
immersion heater
l
346
Type SVKA/SVSA, 950 litres
Heat-up time from 10 to 60 °C
h
12.6
6.3
4.3
Capacity that can be heated with the
immersion heater
435
Immersion heater 12 kW
Rated output in standard operation
kW
4
8
12
Rated voltage
3/N/PE 400 V
∼
/50 Hz
Rated current
A
17.4
Type SVKA/SVSA, 750 litres
Heat-up time from 10 to 60 °C
h
5.0
2.5
1.7
Capacity that can be heated with the
immersion heater
l
346
Type SVKA/SVSA, 950 litres
Heat-up time from 10 to 60 °C
h
6.3
3.2
2.1
Capacity that can be heated with the
immersion heater
l
435