58
5608 741 - 04
Vitodens Rigid and Flex Venting Systems Installation
General Installation Information
(continued)
Single Pipe Venting (Room Air Dependent)
Additional requirements for stainless steel vent pipe material
(continued)
Exhaust vent termination options
Supplier
Boiler Model
Stainless Steel Slip
Joint Starter Adaptor
Vertical Termination Coupling
with Screen
Flexmaster WB1B 26, 35, WB2B 19, 26, 35
B2TA 19, 35, B2HA 19, 28, 35
B2TB 19, 35, B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
3 in. 2SVSVB03
3 in. 2SVSVB03
3 in. 2SVSVB03
3 in. 2SVSVB03
4 in. 2SVSVB04
3 in. 2SVSVT03
3 in. 2SVSVT03
3 in. 2SVSVT03
3 in. 2SVSVT03
4 in. 2SVSVT04
Heat-Fab
WB1B 26, 35, WB2B 19, 26, 35
B2TA 19, 35, B2HA 19, 28, 35
B2TB 19, 35, B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
3 in. 9301VSMN
3 in. 9301VSMN
3 in. 9301VSMN
3 in. 9301VSMN
4 in. 9401VSMN
3 in. 9392
3 in. 9392
3 in. 9392
3 in. 9392
4 in. 9492
ProTech
WB1B 26, 35, WB2B 19, 26, 35
B2TA 19, 35, B2HA 19, 28, 35
B2TB 19, 35, B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
3 in. 300568
3 in. 300568
3 in. 300568
3 in. 300568
4 in. 300569
3 in. 300186
3 in. 300186
3 in. 300186
3 in. 300186
4 in. 300187
Security
Chimneys
WB1B 26, 35, WB2B 19, 26, 35
B2TA 19, 35, B2HA 19, 28, 35
B2TB 19, 35, B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
3 in. CTX-V3
3 in. CTX-V3
3 in. CTX-V3
3 in. CTX-V3
4 in. CTX-V4
Contact
supplier
Other exhaust vent termination options (horizontal installation)
Supplier
Boiler Model
Termination Elbow with
Screen 90° or 45°
Termination Tee
with Screen
Termination Hood
with Screen
Flexmaster WB1B 26, 35, B2TA 19, 35, B2TB 19, 35
WB2B 19, 26, 35, B2HA 19, 28, 35
B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
Contact
supplier
Contact
supplier
Contact
supplier
Heat-Fab
WB1B 26, 35, B2TA 19, 35, B2TB 19, 35
WB2B 19, 26, 35, B2HA 19, 28, 35
B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
Contact
supplier
Contact
supplier
Contact
supplier
ProTech
WB1B 26, 35, B2TA 19, 35, B2TB 19, 35
WB2B 19, 26, 35, B2HA 19, 28, 35
B2HB 19, 26, 35
WB2B 45, 60, B2HA 45, 60, B2HB 45, 57
WB2B 80, 105, B2HA 80, 88, 100, 112, 150
Contact
supplier
Contact
supplier
Contact
supplier
Note:
Minimum vent pipe diameter with stainless steel vent system is 3 in. (76 mm).