Applicability
General Information
Natural gas-fired wall-mounted condensing heating boiler
for weather-responsive operation in closed loop, forced
circulation hot water heating systems for space heating
and domestic hot water (DHW) production.
Models B2HA series boilers are for operation with natural
gas. For a fuel conversion to liquid propane gas (see page
16).
Boiler model must be selected based on an accurate heat
loss calculation of the building. Ensure boiler model is
compatible with connected radiation.
Vitodens 200-W, B2HA series boilers are factory-tested
and calibrated. Further gas valve adjustments are not
typically required during field start-up.
Product Information
CAUTION
The boiler serial number must be provided when
ordering replacement parts. Some replacement parts are
not reverse compatible with previous versions of the
Vitodens 200-W B2HA boiler.
When ordering replacement parts, provide either the
16-digit boiler serial number (on the bar code label) or
the 12-digit ASME/NB serial number, located as shown
underneath boiler front enclosure panel. Refer to page 12
for instructions on how to remove front enclosure panel.
Model No. B2HA 112
Serial No. 7510835
jjjjjjjjj
Model No. B2HA 150
Serial No. 7510836
jjjjjjjjj
IMPORTANT
A
Inox-Radial heat exchanger made from stainless steel
– for high operational reliability and a long service life.
Large heating output in the smallest of spaces
B
Modulating MatriX cylinder burner for extremely
clean combustion and quiet operation
C
Variable speed combustion fan for quiet and
economical
operation
D
Gas and water connections
E
Digital boiler control unit
Multi boiler system
In connection with the installation of a multi boiler system
observe the installation instructions of the multi boiler
system accessories.
Product may not be exactly as shown
Follow the Vitodens Venting System
Installation Instructions to vent this boiler.