79
Calling up coding level 2
■
All
codes are accessible in coding
level 2.
■ Codes that have not been assigned
due to the heating system equipment
level or the setting of other codes are
not displayed.
■ The heating circuit without mixer is
designated
"Heating circuit 1"
and
the heating circuits with mixer as
"Heating circuit 2"
or
"Heating cir-
cuit 3"
.
If the heating circuits were given indi-
vidual designations, the selected des-
ignation and
"HC1"
,
"HC2"
or
"HC3"
appear instead.
Weather-compensated control unit
Constant temperature control unit
The codes are divided into groups
■
"General"
■
"Boiler"
■
"DHW"
■
"Solar"
■
"Heating circuit 1/2/3"
■
"All codes std device"
In this group, all coding addresses (ex-
cept the coding addresses from the
"Solar"
group) are displayed in as-
cending order.
■
"Standard setting"
1
:
"General"
2
:
"Boiler"
3
:
"DHW"
4
:
"Solar"
5
:
"Heating circuit 1"
6
:
"All codes std device"
In this group, all coding addresses are
displayed in ascending order.
7
:
"Standard setting"
Call up code 2
Service menu:
1. Press
OK
and
simultaneously for
approx. 4 s.
2. Press
OK
and simultaneously for
approx. 4 s.
3.
"Coding level 2"
4. Select group of required coding ad-
dress.
5. Select coding address.
6. Select value according to the following
tables and confirm with
OK
.
Service menu:
1. Press
OK
and
å
simultaneously for
approx. 4 s.
2. Press
OK
and
ä
simultaneously for
approx. 4 s.
3. Select
"
2
"
with
Ú
for coding level 2
and confirm with
OK
.
4.
"I"
flashes on the display for the coding
addresses in group 1.
5. Select the group of required coding ad-
dress with
V
/
v
and confirm with
OK
.
6. Select coding address with
V
/
v
.
7. Set value according to the following ta-
bles with
V
/
v
and confirm with
OK
.
Code 2
Calling up coding level 2
5585 174 GB
Service