80
Weather-compensated control unit
Constant temperature control unit
Resetting all codes to their delivered condition
Select
"Standard setting"
.
Note
This also resets codes at coding level 1.
Select
"7"
with
Ú
and confirm with
OK
.
When
" "
flashes, confirm with
OK
.
Note
This also resets codes at coding level 1.
General/group "1"
Select
"General"
for weather-compen-
sated control units (see page 79).
Select
"1"
for constant temperature con-
trol unit (see page 79).
Coding
Coding in the delivered condition
Possible change
00:1
System version 1:
one heating circuit with-
out mixer A1 (heating cir-
cuit 1), without DHW
heating
00:2
to
00:10
For system schemes, see
the following table:
Value
address
00: ...
System
version
Description
2
1
One heating circuit without mixer A1 (heating circuit 1), with
DHW heating (code is set automatically)
3
2,3
One heating circuit with mixer M2 (heating circuit 2), without
DHW heating
4
2,3
One heating circuit with mixer (heating circuit 2), with DHW
heating
5
2,3
One heating circuit without mixer A1 (heating circuit 1) and
one heating circuit with mixer M2 (heating circuit 2), without
DHW heating (code is set automatically)
6
2,3
One heating circuit without mixer A1 (heating circuit 1) and
one heating circuit with mixer M2 (heating circuit 2), with DHW
heating (code is set automatically)
Code 2
Calling up coding level 2
(cont.)