Residual head of integral circulation pump
Residual
head
0 kPa
0
200
400
600
800
1000
Flow rate in l/h
100
200
300
400
0
10
20
30
40
500 50
mbar
1200
100
300
500
700
900
1100
5
50
150 15
250 25
350 35
450 45
550 55
A
B
C
D
E
K
L
F
G
H
M
M
Upper operational limit (integral bypass opens)
Curve
Pump rate, circulation pump
A
10 %
B
20 %
C
30 %
D
40 %
E
50 %
F
60 %
G
70 %
H
80 %
K
90 %
L
100 %
Variable speed solar circuit pump in the Vitodens 242-F
The integral solar circuit pump is a highly efficient circulation pump
with substantially lower power consumption than conventional
pumps.
The min. and max. speed and therefore the pump rate are set via
parameters on the control unit. The control unit transmits the current
speed specifications to the circulation pump via PWM signal.
Type
VI Solar PM2 15-85
Rated voltage
V~
230
Power consumption
– Max.
W
55
– Min.
W
3
Energy efficiency class
A
Vitodens 242-F
(cont.)
46
VIESMANN
VITODENS
5
5853906
Summary of Contents for Vitodens 200-W B2HE
Page 154: ...154 VIESMANN VITODENS...
Page 155: ...VITODENS VIESMANN 155 5853906...