107
Coding in the delivered condition
Possible change
d8:3
Heating program change-
over via input DE3.
E1:1
Do not adjust
E2:50
With remote control:
No display correction for
the actual room tempera-
ture (only for weather-
compensated control
units)
E2:0
to
E2:49
Display correction –5 K
to
Display correction –0.1 K
E2:51
to
E2:99
Display corr0.1 K
to
Display corr4.9 K
E5:0
Do not adjust
E6:...
Only for heating systems
without a heating circuit
with mixer:
Maximum speed of the in-
ternal variable speed
heating circuit pump in %
of the max. speed in
standard mode. Value is
specified by boiler-specif-
ic parameters (only for
weather-compensated
control units)
E6:0
to
E6:100
Maximum speed adjusta-
ble from 0 to 100 %
E7:30
Only for heating systems
without a heating circuit
with mixer:
Minimum speed of the in-
ternal variable speed
heating circuit pump:
30 % of the max. speed
(only for weather-com-
pensated control units)
E7:0
to
E7:100
Minimum speed adjustable
from 0 to 100 % of the max-
imum speed
E8:1
Only for heating systems
without a heating circuit
with mixer:
E8:0
Speed subject to the set-
ting in coding address
"E7"
Code 2
"Heating circuit ..."/group 5
(cont.)
5773 216 GB
Service
Summary of Contents for Vitodens 222-F B2TA series
Page 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Page 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Page 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Page 194: ...194 5773 216 GB...
Page 195: ...195 5773 216 GB...