Checking the burner gasket and burner gauze assembly
Check burner gasket
A
and burner
gauze assembly
E
for possible damage
and replace if required.
A
C
2x
2x
B
D
E
F
1.
Remove electrodes
B
.
2.
Undo two retaining clips
C
on ther-
mal insulation ring
D
and then
remove thermal insulation ring
D
.
3.
Undo two Torx screws and remove
burner gauze assembly
E
with gas-
ket
F
.
4.
Insert new burner gauze assembly
E
with new gasket
F
and secure.
Torque: 5.0 Nm.