Note
Set code "24:1" and then code "24:0" if maintenance is carried out before main-
tenance is displayed; the set maintenance parameters for hours run and inter-
vals are then reset to 0.
1.
Press
c
.
The maintenance scan is active.
2.
Scan maintenance messages with
a
or
b
.
3.
Press
d
, for weather-compen-
sated control units also confirm the
display "Acknowledge: Yes" with
d
.
The "Maintenance" display extin-
guishes and the red fault indicator
continues to flash.
Note
An acknowledged maintenance
message can be redisplayed by
pressing
d
(approx. 3 s).
After maintenance has been carried out
1.
Reset code "24:1" to "24:0".
The red fault indicator extin-
guishes.
Note
If the coding address "24" is not
reset, a new "Maintenance" display
will be shown on Monday at 07:00
h.
2.
If required:
&
Press
c
.
&
Reset burner hours run, burner
starts and consumption (see
page 69).
&
Press
c
.
Further details regarding the individual steps
(cont.)
38