Coding in the delivered condition
Possible change
DHW
56:0
Set DHW temperature
adjustable from 10 to
60 °C
56:1
Set DHW temperature
adjustable from 10 to
above 60 °C
Note
Maximum value subject
to boiler coding card
Observe the maximum
permissible DHW tem-
perature
58:0
Without auxiliary func-
tion for DHW heating
58:10
to
58:60
Input of a second set
DHW value, adjustable
from 10 to 60 °C (observe
the coding addresses
"56" and "63")
63:0
No default interval for
auxiliary function for
DHW heating (only for
constant temperature
control units)
63:1
Auxiliary function for
DHW heating, 1 x daily
63:2
to
63:14
Every 2 days to every 14
days
63:15
2 x daily
65:...
Information regarding
the type of diverter
valve; do not adjust.
65:0
Without diverter valve
65:1
Diverter valve by
Viessmann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
67:40
With the Vitosolic:
Third set DHW tem-
perature = 40 °C
67:0
Without third set DHW
temperature
67:1
to
67:60
Third set DHW tempera-
ture adjustable from 1 to
60 °C (subject to the set-
ting of coding address
"56")
6C:100
Set speed; internal cir-
culation pump with
DHW heating 100 %
6C:0
to
6C:100
Set speed adjustable
from 0 to 100 %
Code 2
(cont.)
48
Coding
5692
731
GB
Summary of Contents for VITODENS 333-F WS3A
Page 113: ...Parts lists cont 113 Parts lists 5692 731 GB ...
Page 114: ...Parts lists cont 114 Parts lists 5692 731 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 731 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 731 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 731 GB ...