101
Rated voltage:
230 V~
Rated frequency:
50 Hz
Rated current:
6.0 A
Safety class:
I
Protection:
IP 20
Permissible ambient temperature
■ during operation:
0 to +40 °C
■ during storage and
transport:
-20 to +65 °C
Control thermostat
and temperature con-
troller setting:
75 °C
Temperature limiter
setting:
100 °C
Line fuse (mains):
max. 16 A
Power consumption
■ Circulation pump:
max. 70 W
■ Control unit:
max. 10 W
Oil fired condensing boiler, type B
23
, C
33x
, C
53x
, C
63x
Rated output
kW
12.9/19.3
16.1/23.5
Burner stage
Stage 1
Stage 2
Stage 1
Stage 2
Rated output
at burner stage
kW
12.9
19.3
16.1
23.5
Power consumption
with circulation pump
W
165
215
178
240
Motor speed
Oil pump drive
min
-1
2880
2880
Capacity
Oil pump
l/h
45
45
Burner version
Two-stage
Two-stage
Product ID
_
-0645 BM 112.3
Specification
Specification
5692 799 GB
Summary of Contents for VITOLADENS 300-W