15
Rated output
kW
12.9/19.3
16.1/23.5
Oil pressure
approx.
*1
bar
8.0-10.5
14.0-17.5
9.0-13.5
16.0-18.5
Max. permissible
vacuum
in the oil feed line
bar
0.35
0.35
0.35
0.35
Oil throughput
kg/h
1.05
1.58
1.53
1.92
approx.
l/h
1.24
1.86
1.80
2.26
Static burner pres-
sure approx.
mbar
8.0-10.5
15.5-19.5
11.0-15.5
17.5-21.0
CO
2
content approx.
■ Test value w/o cap
%
12.2-13.4
12.2-13.2
■ Test value with cap %
12.7-13.9
12.7-13.7
Nozzle gap "a"
mm
3.0
+0.2/-0.3
1.5
+0.2/-0.3
!
Please note
An incorrectly adjusted nozzle gap "a" can result in irregular operation of the
burner and even a fault shutdown.
Always
maintain the stated dimension and check in accordance with the
details on page 19.
Installation position, oil preheater
Position the oil preheater in the recess of the mixer facility in accordance with the
diagram.
*1
Due to nozzle tolerances and varying oil characteristics, the oil pressure may vary
from the values shown.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 799 GB