3.
Set the current date with
a
/
b
.
4.
Confirm with
d
.
Changing the language at the control unit
1.
Press
c
.
The display shows "Select heating
circuit".
2.
Press
d
.
3.
After approx. 4 s press
c
.
4.
Select the required language with
b
.
5.
Confirm with
d
.
Function sequence and possible faults
For further details regarding faults, see page 68.
Display screen
Measures
Control unit is-
sues heat de-
mand
No
Increase set
value and ensure
heat is drawn off
Yes
Oil pre-heating
starts
No
after approx. 10
min
Check the oil pre-
heater, cables
and plug-in con-
nections
Fault
E6
Yes
The fan starts
after max. 10 min
No
Fault
Check the oil pre-
heater, fan,
cables and plug-
in connections
(the oil preheater
has not switched
through; the tem-
perature is not
achieved)
F9
Further details regarding the individual steps