330
420
Roof tile type
Ventilation cross-section in cm
2
Double Roman tile
32
Double-S
30
Taunus tile
27
Harz tile
27
13.7 Collector fixing
Due to the many varieties available, solar collectors can be installed
in almost all types of building, both in new build and modernisation
projects. As required, they can be installed on pitched roofs, flat roofs
and on walls, as well as freestanding on the ground or integrated into
the roof surface.
Viessmann offers universal fixing systems to simplify installation.
These fixing systems are suitable for virtually any form of roof and roof
cover as well as for installation on flat roofs and walls.
Above roof installation
In above roof systems, the collectors and the roof frame are connected.
At each fixing point, a rafter hook, rafter flange or rafter anchor pene-
trates the water-carrying level below the collector. This requires a
completely rain-proof and safe anchorage. The fixing points, and
therefore also any possible defects, are no longer visible post instal-
lation. Maintain the minimum clearances from the roof edge in accord-
ance with DIN 1055 (see page 108).
Required roof area
Add dimension b for each additional collector.
For collector installation, vertical pipes, dimensions of roof area
requirement, see table. For the installation version with horizontal
pipes, interchange dimensions a and b.
Collector
Vitosol-F
Vitosol 200-T, type SPE
Vitosol 200-T, type SP2A
Vitosol 300-T, type SP3B
SV
SH
1.63 m
2
3.26 m
2
1.51 m
2
3.03 m
2
a in mm
2380
1056
2500
2500
2240
2240
b in mm
1056 + 16
2380 + 16
1470 + 44
2640 + 44
1053 + 89
2061 + 89
Design information regarding installation
(cont.)
110
VIESMANN
VITOSOL
13
5822 440 GB