Vitosol-F, type SV
Absorber area in m
2
Static head in m
System capacity in l
Recom. capacity of the ex-
pansion vessel in l
Recom. heat sink
(see page 106)
2.3
5
22.3
18 —
10
25.7
25
15
29.2
4.6
5
24.7
25 2 m uninsulated pipe
10
27.6
—
15
31.0
—
6.9
5
28.5
40 Type 21
10
29.6
0.6 m uninsulated pipe
15
32.9
—
9.2
5
30.3
40 Type 21
10
33.8
15
34.7
—
11.5
5
32.2
40 Type 21
10
35.6
50
15
39.1
13.8
5
34.0
40
10
37.4
50
15
40.9
80
16.1
5
35.8
50
10
39.3
15
42.7
80
18.4
5
37.7
50
10
41.1
80
15
44.6
Vitosol-F, type SH
Absorber area in m
2
Static head in m
System capacity in l
Recom. capacity of the ex-
pansion vessel in l
Recom. heat sink
(see page 106)
2.3
5
22.9
18 —
10
26.4
25
15
29.8
4.6
5
26.0
40 2 m uninsulated pipe
10
28.9
—
15
32.3
—
6.9
5
30.5
40 Type 21
10
31.5
0.6 m uninsulated pipe
15
34.8
50 —
9.2
5
32.9
40 Type 21
10
36.4
15
37.3
50 —
11.5
5
35.4
50 Type 21
10
38.9
15
42.3
80
13.8
5
37.9
50
10
41.3
80
15
44.8
16.1
5
40.4
50
10
43.8
80
15
47.3
18.4
5
42.9
80
10
46.3
15
49.8
Information regarding design and operation
(cont.)
154
VIESMANN
VITOSOL
18
5822 440 GB