6.2 Specification
For locations between 100 and 1000 m from the coast we
recom-
mend
the Vitosol 200-F, type SV2D.
In close proximity to the coast (up to 100 m),
always
install the
Vitosol 200-F, type SV2D.
Vitosol 200-F, type SV2D has a special absorber coating that allows
these collectors to be used in coastal regions.
Note
Viessmann accepts no liability if type SV3C/SH3C is used in these
regions.
Type
SV3C
SH3C
Gross area
(required when applying for subsidies)
m
2
2.51
Absorber area
m
2
2.32
Aperture area
m
2
2.33
Installation position
(see following diagram)
A
(above roof and roof
integration),
C
,
D
B
(above roof and roof in-
tegration),
C
,
D
,
E
Clearance between collectors
mm
21
Dimensions
Width
mm
1056
2380
Height
mm
2380
1056
Depth
mm
90
90
The following values apply to the absorber area:
–
Optical efficiency
%
86.3
–
Heat loss factor k
1
W/(m
2
· K)
3.143
–
Heat loss factor k
2
W/(m
2
· K
2
)
0.023
Thermal capacity
kJ/(m
2
· K)
5.0
5.0
Weight
kg
41
Liquid content
(heat transfer medium)
litres
1.83
2.48
Permiss. operating pressure
(see chapter "Solar expansion vessel")
bar/MPa
6/0.6
Max. stagnation temperature
°C
206
Steam output
– Favourable installation position
W/m
2
60
– Unfavourable installation position
W/m
2
100
Connection
Ø mm
22
E
C
B
A
D
Vitosol 300-F, type SV3 and SH3
(cont.)
VITOSOL
VIESMANN
27
5822 440 GB
6