11.8 Vitocell 100-V, type CVA
For DHW heating
in conjunction with boilers and district heating sys-
tems, as option with electric heater as accessory for DHW cylinders
with 300 and 500 l capacity.
Suitable for the following systems:
■ DHW temperatures up to
95 °C
■ Heating water flow temperature up to
160 °C
■ Operating pressure on the
heating water side
up to
25 bar
(2.5 MPa)
■ Operating pressure on the
DHW side
up to
10 bar (1.0 MPa)
Cylinder capacity
l
160
200
300
500
750
1000
DIN registration number
9W241/11–13 MC/E
Continuous output
for DHW heating from
10 to 45 °C
and a
heating water
flow tempera-
ture of ... at the heating water flow
rate stated below
90 °C
kW
40
40
53
70
123
136
l/h
982
982
1302
1720
3022
3341
80 °C
kW
32
32
44
58
99
111
l/h
786
786
1081
1425
2432
2725
70 °C
kW
25
25
33
45
75
86
l/h
614
614
811
1106
1843
2113
60 °C
kW
17
17
23
32
53
59
l/h
417
417
565
786
1302
1450
50 °C
kW
9
9
18
24
28
33
l/h
221
221
442
589
688
810
Continuous output
for DHW heating from
10 to 60 °C
and a
heating water
flow tempera-
ture of ... at the heating water flow
rate stated below
90 °C
kW
36
36
45
53
102
121
l/h
619
619
774
911
1754
2081
80 °C
kW
28
28
34
44
77
91
l/h
482
482
584
756
1324
1565
70 °C
kW
19
19
23
33
53
61
l/h
327
327
395
567
912
1050
Heating water flow rate
for the stated contin-
uous outputs
m
3
/h
3.0
3.0
3.0
3.0
5.0
5.0
Standby heat loss q
BS
at a temp. differential of 45 K (actual values to
DIN 4753-8).
kWh/
24 h
1.50
1.70
2.20
2.50
3.50
3.90
Dimensions
Length (
7
)
– Incl. thermal insulation
a
mm
581
581
633
859
960
1060
– Excl. thermal insulation
mm
—
—
—
650
750
850
Width
– Incl. thermal insulation
b
mm
608
608
705
923
1045
1145
– Excl. thermal insulation
mm
—
—
—
837
947
1047
Height
– Incl. thermal insulation
c
mm
1189
1409
1746
1948
2106
2166
– Excl. thermal insulation
mm
—
—
—
1844
2005
2060
Height when tilted
– Incl. thermal insulation
mm
1260
1460
1792
—
—
—
– Excl. thermal insulation
mm
—
—
—
1860
2050
2100
Installation height
mm
—
—
—
2045
2190
2250
Weight
incl. thermal insulation
kg
86
97
151
181
295
367
Heating water content
l
5.5
5.5
10.0
12.5
24.5
26.8
Heating surface
m
2
1.0
1.0
1.5
1.9
3.7
4.0
Connections
(male thread)
Heating water flow and return
R
1
1
1
1
1¼
1¼
Cold water, DHW
R
¾
¾
1
1¼
1¼
1¼
DHW circulation
R
¾
¾
1
1
1¼
1¼
Information regarding continuous output
When engineering systems with the specified or calculated continuous
output, select a matching circulation pump. The stated continuous out-
put is only achieved when the rated boiler heating output ≥ continuous
output.
DHW cylinders
(cont.)
88