Vitosol 100-FM/200-FM Installation, Operating and Service
5786 604 - 02
22
Installing Freestanding Installation
(with ballast - for Model SH only)
(continued)
Installation on Flat Roofs
or Freestanding Installation
Note:
See page 16 for numbered component description.
6. Secure two mounting crossbars
qW
diagonally side
by side to the adjustable supports, respectively for
between one and six collectors.
Only one pair of mounting crossbars are supplied for 1 to
6 collectors, two pairs of mounting crossbars are supplied
for 7 to 10 collectors.
7. For added stability, attach connecting ties to each
other where they intersect, using M8 or 5/16” (field
supplied) nut and bolt.
IMPORTANT
Legend
qW
Mounting crossbars