Vitosol 100-FM/200-FM Installation, Operating and Service
5786 604 - 02
32
Additional Installation Information
Sample System Layout
Legend
A
Solar
collector
B
Solar-Divicon (pumping station)
C
Overflow
container
D
Expansion
tank
E
Solar manual filling pump (optional)
F
System fill manifold valve
G
Solar brass elbow, comes with sensor well
H
Solar storage tank
I
Tank temperature sensor
J
Air
separator
K
Solar control unit
L
Collector temperature sensor
(field installed)
M
Fast air vent, c/w shutoff valve *1
P
System pressure gauge
R
Return to collector
S
Supply from collector
*1 Install at least one air vent valve at the highest point
of the system.
WARNING
The domestic hot water temperature must be limited
to 140°F (60°C) by installing a mixing device,
e.g. a thermostatic anti-scald mixing valve.
Refer to the Vitosol System Design Guidelines for
more information on other installation examples
and system types