Vitosol 100-FM/200-FM Installation, Operating and Service
5786 604 - 02
42
Flow Rate - Vitosol 100-FM / 200-FM
Vitosol 100-FM / 200-FM recommended flow rates
*Applies to both SV and SH model
s
High flow mode
USG/min (L/min)
Medium flow mode
USG/min (L/min)
Low flow mode
USG/min (L/min)
1
collector
0.61 (2.32)
--
--
2
collectors
1.22 (4.6)
--
--
3
collectors
1.83 (6.9)
--
--
4
collectors
2.44 (9.2)
--
--
5
collectors
3.05 (11.5)
--
--
6
collectors
3.66 (13.8)
--
--
7
collectors
--
3.15 (12.2)
2.17 (8.1)
8
collectors
--
3.6 (13.6)
2.48 (9.4)
9
collectors
--
4.05 (15.7)
2.79 (10.4)
10
collectors
--
4.5 (17.0)
3.1 (11.7)
11
collectors
--
4.95 (19.1)
3.41 (12.8)
12
collectors
--
5.4 (20.8)
3.72 (14.1)
Check Solar Fluid Flow Rate
Note:
Maximum of 10 Vitosol-FM can be connected in one array with same side piping connections.
Maximum of 12 Vitosol-FM can be connected in one array with opposite side connections.
Start-up
Check Switching Functions of the Solar Control Unit
Refer to the Installation Instructions
of the solar control unit.
Check Electrical Connections
Check the tightness of electrical connections and cable
grommets.
Check the cables for possible damage.