Summary of Contents for VITOSOL 200-F

Page 1: ...ation instructions for contractors VIESMANN Vitosol 200 F Type SVK Flat plate collector for pitched roofs above roof installation for one collector VITOSOL 200 F 5465 555 GB 2 2014 Dispose after insta...

Page 2: ...s Regulations Observe the following when working on this system National installation regulations Statutory regulations regarding the prevention of accidents Statutory regulations regarding envi ronme...

Page 3: ...10 Installation with roof hooks 12 Components 13 Fitting roof hooks 14 Fitting the mounting rails 18 Installation with mounting brackets 18 Components 19 Fitting the mounting bracket and mounting rail...

Page 4: ...tended use presupposes that a fixed installation in conjunction with permissi ble system specific components has been carried out Commercial or industrial usage for a pur pose other than heating the b...

Page 5: ...ng the rafter hooks and mounting rails 2 adjacent rafters are used to fit the raf ter hooks Version I Fitting rafter hook 1 onto counter bat ten C with support bracket 2 Version II Fitting rafter hook...

Page 6: ...ase note Take care to avoid breaking tiles The rafter hook must not be sup ported by the pantiles Observe the dimensions B C 1 2 B 75 C 20 B 3 1 2 1 2 1 5 4 Installation with rafter hooks cont 5465 55...

Page 7: ...7 5 7 5 6 Installation with rafter hooks cont 5465 555 GB...

Page 8: ...8 9 8 Installation with rafter hooks cont 5465 555 GB...

Page 9: ...0 10 x y Maximum deviation from dimensions x and y 10 mm Continue with Installing and connecting the collectors see page 27 Installation with rafter flange For plain tiled and slate roofs Installation...

Page 10: ...after flange 2 Seal 3 Screws 4 Mounting rail 5 Mounting plate 6 Clamping bracket Fitting the rafter flange and mounting rails 2 adjacent rafters are used to fit the raf ter flanges Installation with r...

Page 11: ...11 1 1 3 3 2 2 Installation with rafter flange cont 5465 555 GB...

Page 12: ...ximum deviation from dimensions x and y 10 mm Continue with Installing and connecting the collectors see page 27 Installation with roof hooks For pantiled plain tiled slate and cor rugated sheet roofs...

Page 13: ...ew Spax S 6 x 80 mm 4 Zinc plated countersunk chipboard screw Spax S 5 x 30 mm 5 Roof hook for slate roofs 6 Zinc plated countersunk chipboard screw Spax S 6 x 30 mm 7 Roof hook for plain tiled roofs...

Page 14: ...hooks Pantiles 2 0 6 6 x 1 6 0 1 6 0 y 1 6 0 0 1 8 0 0 x x according to the width of the tile head y 440 mm Dimensions for horizontal fitting of roof hooks see page 18 Installation with roof hooks co...

Page 15: ...ain tiled roof 2 0 6 6 y 1 6 0 0 1 8 0 0 Dimensions for horizontal fitting of roof hooks see page 18 Roof cover y in mm Slate 348 Plain tile 380 Corrugated sheets 207 Installation with roof hooks cont...

Page 16: ...1 Continue with Fitting mounting rails on page 18 Slate 5 6 1 2 Note Fit commercially available lead flashing to protect against the ingress of mois ture Continue with Fitting mounting rails on page...

Page 17: ...e Trim tiles cut off approx 30 mm with an angle grinder Continue with Fitting mounting rails on page 18 Corrugated sheet roof A 8 B 8 9 A Sealing washer on site B Existing roof batten Installation wit...

Page 18: ...1 0 3 3 9 3 9 2 3 9 3 x y 1 2 Maximum deviation from dimensions x and y 10 mm Continue with Mounting the collectors on page 27 Installation with mounting brackets For sheet metal roofs Installation wi...

Page 19: ...racket and mounting rails 1 0 3 1 6 0 0 1 8 0 0 2 0 6 6 Dimensions for horizontal fitting of mounting brackets see page 21 Use on site fixings A to secure the mounting brackets The installation of the...

Page 20: ...20 A 1 2 Screws supplied on site Installation with mounting brackets cont 5465 555 GB...

Page 21: ...21 1 0 3 3 1 6 0 7 9 0 1 6 0 x y 3 4 Maximum deviation from dimensions x and y 10 mm Installation with rafter anchors For tiled roof covers Installation with mounting brackets cont 5465 555 GB...

Page 22: ...fter anchor 2 Mounting rail 3 Seal 4 Mounting plate 5 Clamping bracket 6 Plastic replacement tile if the exist ing tiles are not to be cut Use only on roofs with a pitch of at least 12 Installation wi...

Page 23: ...3 Fitting the rafter hooks and mounting rails 4 0 1 2 4 0 C B 1 6 0 0 1 8 0 0 B Rafter C Batten 2 adjacent rafters are used to fit the raf ter anchors Installation with rafter anchors cont 5465 555 GB...

Page 24: ...24 Installation involving tile trimming 3 4 6 5 7 Continue with step 9 see page 27 Installation with rafter anchors cont 5465 555 GB...

Page 25: ...25 Installation with plastic replacement tiles 4 5 3 Installation with rafter anchors cont 5465 555 GB...

Page 26: ...26 7 6 8 Installation with rafter anchors cont 5465 555 GB...

Page 27: ...from dimensions x and y 10 mm Installing and connecting the collectors Please note Connection pipes must not show any signs of damage Lubricate O ring seals only with the special valve grease provi de...

Page 28: ...28 2 7 90 2 90 3 1 4 4x Installing and connecting the collectors cont 5465 555 GB...

Page 29: ...29 6 B 5 A A Flow connection with sensor well for collector temperature sensor B Return connection Installing and connecting the collectors cont 5465 555 GB...

Page 30: ...7 2x 8 Fitting the collector temperature sensor The collector temperature sensor is part of the standard delivery of the collector connection set Installing and connecting the collectors cont 5465 55...

Page 31: ...31 1 2 3 Fitting the collector temperature sensor cont 5465 555 GB...

Page 32: ...32 12 4 5 6 7 Commissioning Service instructions Vitosol 200 F type SVK and SVKA Fitting the collector temperature sensor cont 5465 555 GB...

Page 33: ...33 5465 555 GB...

Page 34: ...34 5465 555 GB...

Page 35: ...35 5465 555 GB...

Page 36: ...ropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann com Viessmann Werke GmbH Co KG D 35107 Allendorf Telephone 49 6452 70 0 Fax 49 6452 70 2780 www viessmann com 5...