Solar System Design Guide
6020 457 - 01
46
Required Installation Area (Sloped Roofs) - Vitosol 200-FM, Type SH
Vitosol 200-FM SH2F Array Dimensions
Slope Roof Installation
Collector Array Weight
(Collectors, racking, fittings & fluid)
Number of
Collectors
Dimension "a"
Dimension "b"
in.
(mm)
in.
(mm)
lb.
(kg)
1
Collector
41
c
(1056)
95
a
(2422)
124
(56)
2
Collectors
41
c
(1056)
190
c
(4844)
240
(109)
3
Collectors
41
c
(1056)
286
(7266)
355
(161)
4
Collectors
41
c
(1056)
381
b
(9688)
471
(214)
5
Collectors
41
c
(1056)
476
c
(12110)
587
(266)
6
Collectors
41
c
(1056)
572
a
(14532)
702
(319)
7
Collectors
41
c
(1056)
667
b
(16954)
821
(373)
8
Collectors
41
c
(1056)
762
c
(19376)
935
(424)
9
Collectors
41
c
(1056)
858
a
(21798)
1054
(478)
10
Collectors
41
c
(1056)
953
b
(24220)
1166
(529)
11
Collectors
41
c
(1056)
1049
(26642)
1285
(583)
12
Collectors
41
c
(1056)
1144
a
(29064)
1400
(635)
For horizontal collectors installed between 10° - 80° degrees from the horizontal plane (ground)
Note:
It is recommended that a minimum service
clearance of 12 in. (305 mm) should be added
to each end of the collector array. This allows for
ease of installation and servicing of the solar supply
and return connections.
Design Information