Freestanding Installation
30
Overview of System Installation
This installation method is best suited
for DHW or pool systems with constant
loads.
This method is not recommended for
applications that combine DHW and
space heating supplement or any
application where long periods of
stagnation are expected.
If this installation method is used for
applications that combine DHW and
space heating supplement, a heat
rejection circuit must be used to avoid
collector stagnation.
This installation method can be used for
flat roofs or ground mounting. Support
frames can be attached to ballast
weight, concrete posts or to
substructural frames.
If several collectors are arranged parallel
behind each other, keep a distance of
“z” between the front fixing leg of the
1st row and the front fixing leg of the
next row. Refer to page 32 for
determining the collector row distance
“z”.
Align the collector panel towards the
south.
5
3
6
8
5
3
8
v
1
.1
IMPORTANT